Universal foam admixing system for fire-fighting vehicles FACS
The FACS control system represents universal foam admixing system that is intended for stationary and mobile fire-fighting vehicles.
The FACS control system is fully modular and can be modified or extended according to customer requirements.
FACS control system consists of three main units:
- central control unit FCU
- multifunctional display module MFD
- throttle valve with stepping motor
Individual units in FACS control system are interconnected through industrial bus CAN (Controller Area Network) with higher layer protocol (HLP) CANaerospace.
FCU and MFD units allow operational parameters recording and their archiving on PC through the serial communication port RS-232C. Each unit is also equipped with autodiagnostic functions to prevent emergency or error conditions.
Individual unit description
Multifunctional display FACS-MFD
The FACS-MFD unit displays operational parameters, such as:
- percentage of admixing foam
- water and admixing foam flow
- water turret position (in cooperation with WTCS control system)
The FACS-MFD unit allows archiving parameters of fire-fighting actions (maximum 100 records).
Central admixing foam control unit FACS-FCU
The FACS-FCU control unit measures water and admixing foam flow and on the basis of desired ration controls a throttle valve that regulates amount of foam admixed with water.
Admixing ratio can be set from 0.1 up to 99.9%.
Throttle valve with stepping motor unit FACS-TVC
The FACS-TVC unit regulates by the means of throttle valve amount of foam that is admixed with water. Throttle valve mechanism is self-locking, closing position is indicated by a position sensor. For emergency cases hand control of throttle valve is still possible.
FACS control system characteristics
- easy operation
- fully electronic-controlled admixing with emergency hand operation possibility
- high accuracy of flow measurement
- admixing regulation with resolution 0.1%
- autodiagnostic functions
- user and service operational mode
- user configurable (calibration and regulation constants setting)
- czech and english language version (can be extended to any other specific language)
- ability to preset several admixing ratios (0.1 up to 99%) for various types of foams (e.g. PYROCOOL, etc.)
- system modularity and openess
- easy reconfiguration and ability to extend according to customer requirements
- mechanical robustness and high reliability
- wide range of operational temperatures
The FACS control system is ready to full cooperation with Water Turret Control System WTCS.
Technical specification
| Supply voltage: | 24V DC |
| Supply voltage range: | 23V až 32V DC |
| Tolerance against reversity of polarity: | yes |
| Operational temperature: | -20 up to +60°C |
| Storage temperature: | -40 up to +80°C |
| Foam standard flow range: | 0 to 200 l/min |
| Extended foam flow range: | 0 to 360 l/min |
| Admixing resolution: | 0.1% |
| Conformity with standards: | ISO 7637-2:1998, CISPR 12:1997, IEC 61000-4-3:1996, IEC 61000-4-2:1997 |
Application of FACS
Mobile fire-fighting vehicles manufactured by THT s.r.o., Polička, Czech Republic.
Mobile fire-fighting vehicles manufactured by WAWRZASZEK, Poland.